Izimo ezidingekayo zokufakwa kwama-boilers egesi kaphethiloli ezakhiweni eziphakeme
1. Amakamelo okushisa amafutha kanye negesi yegesi kanye namakamelo e-transformer kufanele ahlelwe esitezi sokuqala sesakhiwo noma eduze nodonga olungaphandle, kodwa isiteji sesibili kufanele sisebenzise ukucindezela okuvamile (okubi) ukucindezela uwoyela wamafutha kanye nama-boilers wegesi..Lapho ibanga eliphakathi kwegumbi le-boiler yegesi kanye nephaseji yokuphepha lingaphezu kuka-6.00m, kufanele lisetshenziswe ophahleni.
Amabhola asebenzisa igesi anesisindo esihlobene (isilinganiso sokuminyana komoya) esikhulu noma esilingana no-0.75 njengophethiloli awakwazi ukubekwa endaweni engaphansi noma engaphansi kwesakhiwo.
2. Iminyango yegumbi le-boiler kanye negumbi le-transformer kufanele iholele ngqo ngaphandle noma endaweni ephephile.I-overhang engashi enobubanzi obungekho ngaphansi kuka-1.0m noma udonga lwefasitela olunobude obungekho ngaphansi kuka-1.20m luzosetshenziswa ngaphezu komnyango nezimbobo zamafasitela odonga lwangaphandle.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

3. Amakamelo e-boiler, amakamelo e-transformer nezinye izindawo kufanele ahlukaniswe izindonga zokuhlukanisa ezingashi ngesilinganiso sokumelana nomlilo esingekho ngaphansi kuka-2.00h kanye nephansi ngesilinganiso sokumelana nomlilo se-1.50h.Akufanele kube nezimbobo ezindongeni ezihlukanisayo naphansi.Lapho iminyango namafasitela kufanele kuvulwe odongeni lokuhlukanisa, iminyango yomlilo namafasitela anesilinganiso sokumelana nomlilo esingekho ngaphansi kuka-1.20h kuyosetshenziswa.
4. Uma igumbi lokugcina uwoyela limiswa ekamelweni lokubilisa, umthamo walo ophelele wokugcina akufanele udlule u-1.00m3, futhi i-firewall kufanele isetshenziselwe ukuhlukanisa igumbi lokugcina uwoyela kubhayela.Uma umnyango udinga ukuvulwa ku-firewall, kuzosetshenziswa umnyango womlilo we-Class A.
5. Phakathi kwamakamelo e-transformer naphakathi kwamakamelo e-transformer namagumbi okusabalalisa amandla, izindonga ezingashi ezinesilinganiso sokumelana nomlilo esingekho ngaphansi kuka-2.00h kufanele zisetshenziswe ukuze zihlukanise.
6. Ama-transformer kawoyela acwiliswe ngowoyela, amagumbi okushintsha anothile ngowoyela, namakamelo ama-capacitor anamandla kagesi kufanele asebenzise okokusebenza ukuvimbela ukusakazeka kukawoyela.Ngaphansi kwe-transformer yamandla egxiliwe ngamafutha, imishini yokugcina amafutha ephuthumayo egcina wonke amafutha ku-transformer kufanele isetshenziswe.
7. Umthamo webhayela kufanele uhambisane nezinhlinzeko ezifanele zendinganiso yamanje yobuchwepheshe “Ikhodi Yokuklanywa Kwezindlu Zokubhoyela” GB50041.Umthamo ophelele wama-transformer amandla acwiliswe ngamafutha akufanele ube mkhulu kuno-1260KVA, futhi umthamo we-transformer eyodwa akufanele ube mkhulu kuno-630KVA.
8. Imishini ye-alamu yomlilo kanye nezinhlelo zokucisha umlilo ezizenzakalelayo ngaphandle kwe-halon kufanele zisetshenziswe.
9. Amakamelo obhayela wegesi kanye nowoyela kufanele asebenzise izinsiza zokusiza ukucindezela okungaze kube ukuqhuma kanye nezinhlelo ezizimele zokungenisa umoya.Lapho igesi isetshenziswa njengophethiloli, umthamo wokungenisa umoya akufanele ube ngaphansi kwezikhathi eziyisi-6/h, futhi imvamisa yokukhipha okuphuthumayo akufanele ibe ngaphansi kwezikhathi eziyi-12/h.Lapho amafutha ophethiloli asetshenziswa njengophethiloli, umthamo wokungenisa umoya akufanele ube ngaphansi kwezikhathi ezi-3/h, futhi umthamo wokungenisa umoya onezinkinga akufanele ube ngaphansi kwezikhathi ezi-6/h.