STEAM GENERATOR

STEAM GENERATOR

  • 360kw Electric Industrial Steam Generator

    360kw Electric Industrial Steam Generator

     How to save time and effort in fruit wine fermentation?

    There are countless types of fruits in the world, and regular consumption of fruits will also be beneficial to your health, but frequent consumption of fruits can also make people bored, so many people will make fruit into fruit wine.
    The brewing method of fruit wine is simple and easy to master, and the alcohol content in the fruit wine is low, which is beneficial to health. Some common fruits in the market can also be made into fruit wine.
    The technological process of fruit wine brewing: fresh fruit → sorting → crushing, destemming → fruit pulp → separation and extraction of juice → clarification → clear juice → fermentation → barrel pouring → wine storage → filtration → cold treatment → blending → filtration → finished product.
    Fermentation is an important step in fruit wine brewing. It uses the fermentation of yeast and its enzymes to metabolize the sugar in fruit or fruit juice into alcohol, and uses it to inhibit the growth of harmful microorganisms.

  • 90kw Industrial Steam boiler

    90kw Industrial Steam boiler

    The influence of steam generator outlet gas flow rate on temperature!
    The influencing factors of the temperature change of the superheated steam of the steam generator mainly include the change of the temperature and flow rate of the flue gas, the temperature and flow rate of the saturated steam, and the temperature of the desuperheating water.
    1. The influence of flue gas temperature and flow velocity at the furnace outlet of the steam generator: when the flue gas temperature and flow velocity increase, the convective heat transfer of the superheater will increase, so the heat absorption of the superheater will increase, so the steam The temperature will rise.
    There are many reasons that affect the flue gas temperature and flow rate, such as the adjustment of the amount of fuel in the furnace, the strength of combustion, the change of the nature of the fuel itself (that is, the change of the percentage of various components contained in coal), and the adjustment of excess air. , the change of burner operation mode, the temperature of the steam generator inlet water, the cleanliness of the heating surface and other factors, as long as any one of these factors changes significantly, various chain reactions will occur, and the It is directly related to the change of flue gas temperature and flow rate.
    2. The influence of the saturated steam temperature and flow rate at the superheater inlet of the steam generator: when the saturated steam temperature is low and the steam flow rate becomes larger, the superheater is required to bring more heat. Under such circumstances, it will inevitably cause changes in the working temperature of the superheater, so it directly affects the temperature of the superheated steam.

  • 64kw Electric Steam Generator

    64kw Electric Steam Generator

    A steam generator is an industrial boiler that heats water to a certain temperature and generates high-temperature steam. It is a large thermal energy device. During the working process of the boiler, the enterprise must consider its use cost to ensure that it conforms to the principle of economical and practical use and minimize the cost.
    Boiler room construction and its material costs
    The construction of the steam boiler boiler room belongs to the scope of civil engineering, and the construction standards must comply with the relevant provisions of the “Steam Boiler Regulations”. Boiler room water treatment agents, deslagging agents, lubricating fluids, reducing agents, etc. are billed according to the total annual consumption, and discounts are apportioned per ton of steam, and are included in the fixed cost when calculating.
    But the steam generator does not need to build a boiler room, and the cost is negligible.

  • 1080kw Electric Steam Generator

    1080kw Electric Steam Generator

    Factory production consumes a lot of steam every day. How to save energy, reduce energy consumption, and reduce the operating costs of enterprises is a problem that every business owner is very concerned about. Let’s cut to the chase. Today we will talk about the cost of producing 1 ton of steam by steam equipment on the market. We assume 300 working days a year and the equipment runs 10 hours a day. The comparison between Nobeth steam generator and other boilers is shown in the table below.

    Steam equipment Fuel energy consumption Fuel unit price  1 ton of steam energy consumption (RMB/h) 1-year fuel cost
    Nobeth Steam Generator 63m3/h 3.5/m3 220.5 661500
    Oil boiler 65kg/h 8/kg 520 1560000
    gas boiler 85m3/h 3.5/m3 297.5 892500
    Coal-fired boiler 0.2kg/h 530/t 106 318000
    electric boiler 700kw/h 1/kw 700 2100000
    Biomass boiler 0.2kg/h 1000/t 200 600000

    clarify:

    Biomass boiler 0.2kg/h 1000 yuan/t 200 600000
    Fuel cost of 1 ton of steam for 1 year
    1. The unit price of energy in each region fluctuates greatly, and the historical average is taken. For details, please convert according to the actual local unit price.
    2. The annual fuel cost of coal-fired boilers is the lowest, but the tail gas pollution of coal-fired boilers is serious, and the state has ordered to ban them;
    3. The energy consumption of biomass boilers is also relatively low, and the same waste gas emission problem has been partially banned in the first and second tier cities in the Pearl River Delta;
    4. Electric boilers have the highest energy consumption cost;
    5. Excluding coal-fired boilers, Nobeth steam generators have the lowest fuel costs.

  • 54kw Electric Steam Generator

    54kw Electric Steam Generator

    Everyone knows that a steam generator is a device that generates high-temperature steam by heating water. These high-temperature steam can be used for heating, disinfection, sterilization, etc., so what is the process of steam generator generating steam? Briefly explain the overall process of the steam generator to generate steam for you, so that you can better understand our steam generator.

  • 18kw Electric Steam Generator

    18kw Electric Steam Generator

    The setting of the steam generator expansion tank is basically indispensable for the atmospheric pressure steam generator. It can not only absorb the thermal expansion caused by the heating of the pot water, but also increase the water volume of the steam generator to avoid being evacuated by the water pump. It can also To accommodate the circulating hot water that flows back if the opening and closing valve closes laggardly or is not closed tightly when the pump stops.
    For the atmospheric pressure hot water steam generator with a relatively large drum capacity, some space can be left on the upper part of the drum, and this space must be connected to the atmosphere. For common steam generators, it is necessary to set up a steam generator expansion tank communicating with the atmosphere. The steam generator expansion tank is usually located above the steam generator, the height of the tank is usually about 1 meter, and the capacity is generally not more than 2m3.

  • 90kw Electric Steam Generator for Food Industry

    90kw Electric Steam Generator for Food Industry

    A steam generator is a special kind of equipment. Well water and river water cannot be used according to regulations. Some people are curious about the consequences of using well water. Because there are many minerals in the water, it is not treated with water. While some water may appear clear without turbidity, minerals in untreated water undergo more chemical reactions after repeated boiling in a boiler. They will stick to the heating tubes and level controls.

  • 60kw Electric Steam Generator for bakery

    60kw Electric Steam Generator for bakery

    When baking bread, the bakery can set the temperature based on the size and shape of the dough. Temperature is even more important for bread toasting. How do I keep the temperature of my bread oven within range? At this time, an electric heating steam generator is needed. The electric steam generator emits steam in 30 seconds, which can continuously control the temperature of the oven.
    Steam can gelatinize the skin of bread dough. During gelatinization, the skin of the dough becomes elastic and tough. When the bread encounters cold air after baking, the skin will shrink, forming a crunchy texture.
    After the bread dough is steamed, the surface humidity changes, which can prolong the drying time of the skin, keep the dough from deforming, prolong the expansion time of the dough, and the volume of the baked bread will increase and expand.
    The temperature of water vapor is greater than 100°C, spraying on the surface of the dough can transfer heat to the dough.
    Good bread making requires controlled steam introduction. The entire baking process does not use steam. Usually only in the first few minutes of the bake phase. The amount of steam is more or less, the time is long or short, and the temperature is high or low. Adjust according to the actual situation. Tengyang bread baking electric steam generator has fast gas production speed and high thermal efficiency. The power can be adjusted in four levels, and the power can be adjusted according to the demand of steam volume. It controls the amount of steam and temperature well, making it great for bread baking.

  • 360kw Electric Steam Generator

    360kw Electric Steam Generator

    Common faults and solutions of electric heating steam generator:


    1. The generator cannot generate steam. Cause: The switch fuse is broken; the heat pipe is burned; the contactor does not work; the control board is faulty. Solution: Replace the fuse of the corresponding current; Replace the heat pipe; Replace the contactor; Repair or replace the control board. According to our maintenance experience, the most common faulty components on the control board are two triodes and two relays, and their sockets are in poor contact. In addition, various switches on the operation panel are also prone to failure.

    2. The water pump does not supply water. Reasons: the fuse is broken; the water pump motor is burned; the contactor does not work; the control board is faulty; some parts of the water pump are damaged. Solution: replace the fuse; repair or replace the motor; replace the contactor; replace damaged parts.

    3. The water level control is abnormal. Reasons: electrode fouling; control board failure; intermediate relay failure. Solution: remove the electrode dirt; repair or replace the control board components; replace the intermediate relay.

     

    4. The pressure deviates from the given pressure range. Reason: deviation of pressure relay; failure of pressure relay. Solution: readjust the given pressure of the pressure switch; replace the pressure switch.

  • 54kw Electric Steam Generator

    54kw Electric Steam Generator

    How to use, Maintenance and Repair of Electric Heating Steam Generator
    In order to ensure the normal and safe operation of the generator and prolong the service life of the equipment, the following rules of use should be observed:

    1. The medium water should be clean, non-corrosive and impurity-free.
    Generally, soft water after water treatment or water filtered by a filter tank is used.

    2. In order to ensure that the safety valve is in good condition, the safety valve should be artificially exhausted 3 to 5 times before the end of each shift; if the safety valve is found to be lagging or stuck, the safety valve must be repaired or replaced before it can be put into operation again.

    3. The electrodes of the water level controller should be cleaned regularly to prevent the electric control failure caused by electrode fouling. Use a #00 abrasive cloth to remove any buildup from the electrodes. This work must be done with no steam pressure on the equipment and with the power cut off.

    4. In order to ensure that there is no or little scaling in the cylinder, the cylinder must be cleaned once every shift.

    5. In order to ensure the normal operation of the generator, it must be cleaned once every 300 hours of operation, including electrodes, heating elements, inner walls of cylinders, and various connectors.

    6. In order to ensure the safe operation of the generator; the generator must be checked regularly. Regularly inspected items include water level controllers, circuits, the tightness of all valves and connecting pipes, the use and maintenance of various instruments, and their reliability. and precision. Pressure gauges, pressure relays and safety valves must be sent to the superior measurement department for calibration and sealing at least once a year before they can be used.

    7. The generator should be inspected once a year, and the safety inspection should be reported to the local labor department and carried out under its supervision.

  • 48kw Electric Steam Generator

    48kw Electric Steam Generator

    The principle of electric heating steam generator
    The working principle of the electric heating steam generator is: when the water supply system supplies water to the cylinder, when the water level rises to the working water level line, the electric heating element is powered on through the water level controller, and the electric heating element works. When the water level in the cylinder rises to a high water level, the water level controller controls the water supply system to stop supplying water to the cylinder. When the steam in the cylinder reaches the working pressure, the required pressure steam is obtained. When the steam pressure rises to the set value of the pressure relay, the pressure relay will act; cut off the power supply of the heating element, and the heating element will stop working. When the steam in the cylinder drops to the lower value set by the pressure relay, the pressure relay will act and the heating element will work again. In this way, an ideal, certain range of steam is obtained. When the water level in the cylinder drops to a low level due to evaporation, the machine can automatically cut off the power supply of the heating element to protect the heating element from being burned out. While cutting off the heating element power supply, the electric bell alarm sounds and the system stops working.

  • 90kg Industrial steam Generator

    90kg Industrial steam Generator

    How to judge whether the steam boiler is energy-saving

    For the majority of users and friends, it is very important to purchase a boiler that can save energy and reduce emissions when purchasing a boiler, which is related to the cost and cost performance of the subsequent use of the boiler. So how do you see whether the boiler is an energy-saving type when purchasing a boiler? Nobeth has summarized the following aspects to help you make better boiler selection.
    1. When designing the boiler, the reasonable selection of equipment should be carried out first. In order to ensure that the safety and energy saving of industrial boilers meet the requirements of users, it is necessary to choose the appropriate boiler according to the local conditions, and design the boiler type according to the scientific and reasonable selection principle.
    2. When selecting the type of boiler, the fuel of the boiler should also be correctly selected. The type of fuel should be reasonably selected according to the type, industry, and installation area of ​​the boiler. Reasonable coal blending, so that the moisture, ash, volatile matter, particle size, etc. of the coal meet the requirements of imported boiler combustion equipment. At the same time, encourage the use of new energy sources such as straw briquettes as alternative fuels or blended fuels.
    3. When selecting fans and water pumps, it is necessary to choose new high-efficiency and energy-saving products, and not to choose outdated products; match the water pumps, fans and motors according to the operating conditions of the boiler to avoid the phenomenon of “big horses and small carts”. Auxiliary machines with low efficiency and high energy consumption should be modified or replaced with high-efficiency and energy-saving products.
    4. Boilers generally have the highest efficiency when the rated load is 80% to 90%. As the load decreases, the efficiency will also decrease. Generally, it is sufficient to select a boiler whose capacity is 10% larger than the actual steam consumption. If the selected parameters are not correct, according to the series standards, a boiler with a higher parameter can be selected. The selection of boiler auxiliary equipment should also refer to the above principles to avoid “big horses and small carts”.
    5. To reasonably determine the number of boilers, in principle, the normal inspection and shutdown of the boilers should be considered.